Performance Standard: Cracks in basement walls shall not exceed 1 /8inch in width or in vertical displacement. Corrective Measure: Cracks that exceed the performance standard will be thoroughly cleaned, filled, and troweled level with a latex-fortified cement mixture or other material designed to fill cracks and bond concrete.