Performance Standard: During prolonged cold spells ice is likely to build up at the eaves of a roof. This condition occurs when snow and ice accumulat...
Read MorePerformance Standard: Roof sheathing shall not bow more than ½ inch in 2 feet. Corrective Measure: The remodeler will straighten bowed roof sheathing...
Read MorePerformance Standard: Insulation shall be installed in accordance with applicable energy code and building code requirements. Corrective Measure: The ...
Read MorePerformance Standard: Because of the flow of water and pipe expansion, the water pipe system will emit some noise. However, the pipes should not make ...
Read MorePerformance Standard: Sewers, fixtures, and drains shall operate properly. Corrective Measure: The remodeler will not be responsible for sewers, fixtu...
Read MorePerformance Standard: Cracks and chips in surfaces of bathtubs and sinks can occur when surfaces are hit with sharp or heavy objects. Corrective Measu...
Read MorePerformance Standard: Plumbing fixtures, appliances, and trim fittings shall comply with their manufacturer’s standards. Corrective Measure: The...
Read MorePerformance Standard: Tubs and showers shall not leak. Corrective Measure: The remodeler will repair tub or shower leaks by sealing the faucet covers ...
Read MorePerformance Standard: All on-site service connections to the municipal water main or private water supply are the responsibility of the remodeler. Cor...
Read MorePerformance Standard: Drain, waste, vent, and water pipes shall be adequately protected to prevent freezing as required by the applicable plumbing cod...
Read MorePerformance Standard: No valve or faucet shall leak because of defects in material or workmanship. Corrective Measure: The remodeler will repair or re...
Read MorePerformance Standard: Condensation on pipes may result at certain combinations of temperature and indoor humidity. Corrective Measure: None....
Read MorePerformance Standard: No leaks of any kind shall exist in any soil, waste, vent, or water pipe. Corrective Measure: The remodeler will make repairs to...
Read MorePerformance Standard: Condensation in the crawl space shall not result from failure to provide adequate ventilation as required by code. Condensation ...
Read MorePerformance Standard: Flowing or trickling water on interior crawl space surfaces is unacceptable. Corrective Measure: The remodeler will take the nec...
Read MorePerformance Standard: Leaks resulting in actual trickling of water shall be repaired. Leaks caused by landscaping improperly installed by the owner, o...
Read MorePerformance Standard: Dampness caused by wicking through the basement walls or floor and condensation of water vapor on cool walls and floor are not t...
Read MorePerformance Standard: Refrigerant lines shall not leak during normal operation. Corrective Measure: The remodeler will repair leaking refrigerant li...
Read MorePerformance Standard: None. Corrective Measure: Condensation lines will clog eventually under normal use. The remodeler will provide unobstructed cond...
Read MorePerformance Standard: If air-conditioning is installed by the remodeler, the cooling system shall be capable of maintaining a temperature of 78 degree...
Read MorePerformance Standard: The heating system shall be capable of producing an inside temperature of 70 degrees Fahrenheit, as measured in the center of ea...
Read MorePerformance Standard: Ductwork shall remain intact and securely fastened. Corrective Measure: The remodeler will reattach and re-secure all separated ...
Read MorePerformance Standard: The stiffening of the ductwork and the gauge of the metal used shall be such that ducts do not “oil can.” The boomin...
Read MorePerformance Standard: When metal is heated, it expands, and when cooled, it contracts. The resulting “ticking” or “crackling” ...
Read MorePerformance Standard: Gaps between miter edges in trim and molding shall not exceed 1/16 inch. Corrective Measure: The remodeler will repair gaps exce...
Read MorePerformance Standard: Tile, brick, marble, and stone flooring shall not crack or loosen. Corrective Measure: The remodeler will replace cracked tiles,...
Read MorePerformance Standard: Cups in strip oak floor boards shall not exceed 1/16 inch in depth in a 3-inch maximum span measured perpendicular to the long a...
Read MorePerformance Standard: Exposure to natural light may cause spots on and minor fading of the carpet. Corrective Measure: None.
Read MorePerformance Standard: The wall covering shall not peel off the walls. Corrective Measure: The remodeler will reattach or replace the loose wall coveri...
Read MorePerformance Standard: Clear finishes on interior woodwork shall not deteriorate during the warranty period. However, clear finishes used on exterior s...