Observation: Concrete work is pitting, scaling, or spalling.

Performance Standard: Concrete surfaces shall not disintegrate to the extent that the aggregate is exposed and loosened under normal conditions of wea...

Read More

Observation: Concrete floors or slabs are uneven.

Performance Standard: Except for basement floors or where a floor or portion of floor has been designed for specific drainage purposes, concrete floor...

Read More

Observation: Wood decking board has nail head protruding.

Performance Standard: Nail heads shall not protrude from the floor of the wood deck during the warranty period. Corrective Measure: The remodeler will...

Read More

Observation: Wood decking boards are split, warped, or cupped.

Performance Standard: At the time the job is accepted, splits, warps, and cups in wood decking boards shall not exceed the allowances established by t...

Read More

Observation: Wood floor is out of level.

Performance Standard: No point on the surface of a wood floor shall be more than 1/2 inch higher or lower than any other point on the surface within 2...

Read More

Observation: Wood floor is out of square.

Performance Standard: The diagonal of a triangle with sides of 12 feet and 16 feet along the edges of the floor shall be no more than 1/2 inch more no...

Read More

Observation: Wood floors are uneven.

Performance Standard: Floors shall not have more than a 1/4 inch ridge or depression within any 32-inch measurement when measured parallel to the jois...

Read More

Observation: Wood deck railing lacks rigidity.

Performance Standard: Wood deck railings shall be attached to structural members in accordance with applicable codes. Corrective Measure: The remodele...

Read More

Observation: Stain color varies on wood deck

Performance Standard: Stain color variations are not acceptable only if they result from poor workmanship such as improper stain application or failur...

Read More

Observation: Wood deck is out of level.

Performance Standard: No point on the deck surface shall be more than 3/4 inch higher or lower than any other deck surface point within 20 feet on a l...

Read More

Observation: Railings on wood deck contain slivers in exposed areas.

Performance Standard: Railings on wood decks shall not contain slivers longer than 1/8 inch in exposed areas at the time the job is accepted. Correcti...

Read More

Observation: Spaces between decking are not uniform.

Performance Standard: The spaces on opposite sides of individual deck boards shall not differ in average width by more than 1/4 inch at the time the j...

Read More

Observation: Wood deck is springy or shaky.

Performance Standard: All structural members in a wood deck shall be sized, and fasteners spaced, according to appropriate building codes, National Fo...

Read More

Observation: The walls are bowed.

Performance Standard: All interior and exterior walls have slight variances on their finished surfaces. Bowing of walls shall not blemish the wallR...

Read More

Observation: Walls are out of plumb.

Performance Standard: Walls shall not be more than 1/4 inch out of plumb for any 32-inch vertical measurement. Corrective Measure: The remodeler will ...

Read More

Observation: Wood beam or post is cupped.

Performance Standard: Beams and posts, especially those 31/2 inches or greater in thickness (which normally are not kiln dried) will sometimes cup as ...

Read More

Observation: Wood beam or post is twisted or bowed.

Performance Standard: Beams and posts, especially those 31/2 inches or greater in thickness (which normally are not kiln dried) will sometimes twist o...

Read More

Observation: Wood beam or post is split.

Performance Standard: Beams and posts, especially those 3 1/2 inches or greater in thickness (which normally are not kiln dried) will sometimes split ...

Read More

Observation: Nails on wood deck are “bleeding.”

Performance Standard: Nail stains extending more than 1/2 inch from the nail and readily visible from a distance of more than 3 feet are not acceptabl...

Read More

Observation: Grade markings show on deck floor boards.

Performance Standard: Grade markings shall not be visible on the tops of deck floorboards, except where the grain of the wood requires the mark to be ...

Read More

Observation: Interior stair railing lacks rigidity.

Performance Standard: Interior stair railings shall be attached to structural members in accordance with applicable codes. Corrective Measure: The rem...

Read More

Observation: Interior stair tread deflects too much.

Performance Standard: The maximum vertical deflection of an interior stair tread shall not exceed 1/8 inch at 200 pounds force.  Corrective Measure: ...

Read More

Observation: Exterior walls leak because of inadequate caulking.

Performance Standard: Joints and cracks in exterior wall surfaces and around openings shall be properly caulked to exclude the entry of water. Correct...

Read More

Observation: Floors squeak or the subfloor appears loose.

Performance Standard: Squeaks caused by a loose subfloor are unacceptable, but totally squeak-proof floors cannot be guaranteed. Corrective Measure: T...

Read More

Observation: Cracks exist between interior stair risers, treads, and/ or skirts.

Performance Standard: Cracks between adjoining parts that are designed to meet flush shall not exceed 1/8 inch in width. Corrective Measure: The remod...

Read More

Observation: Cracks exist between interior stair railing parts.

Performance Standard: Cracks between interior stair rail parts shall not exceed 1/8 inch in width. Corrective Measure: The remodeler will ensure that ...

Read More

Observation: The surface of high pressure laminates on counter tops is cracked or chipped.

Performance Standard: Counter tops shall be free of cracks and chips at the time the job is accepted. Cracks or chips occurring after acceptance of th...

Read More

Observation: Counter tops are not level.

Performance Standard: Counter tops shall be no more than 1/4 inch in 12 feet out of parallel with the floor. If the floor is not level, the counter to...

Read More

Observation: The joints of high pressure laminates on counter tops are delaminated.

Performance Standard: Counter tops fabricated with high pressure laminate coverings shall not delaminate. Corrective Measure: The remodeler will repla...

Read More

Observation: Cabinet is warped.

Performance Standard: Cabinet warpage shall not exceed 1/4 inch as measured from the face frame to the point of furthermost warpage, with the door or ...

Read More