Performance Standard: Painted and finished surfaces shall be free of observable mildew and fungus at the time the job is completed. However, mildew or...
Read MorePerformance Standard: Painted or finished surfaces shall be free of observable mildew and fungus at the time the job is completed. However, mildew or ...
Read MorePerformance Standard: Cups exceeding 1/8 inch in 51/2 inches are unacceptable. Corrective Measure: The remodeler will repair defects exceeding the per...
Read MorePerformance Standard: Bows and twists exceeding 5/16 inch in 8 feet are unacceptable. Corrective Measure: The remodeler will repair defects exceeding ...
Read MorePerformance Standard: Splits wider than 1/8 inch are unacceptable. Corrective Measure: The remodeler will repair splits by filling with a permanent fi...
Read MorePerformance Standard: Joints between exterior trim elements, including siding and masonry, shall not result in joints opened wider than 3/8 inch. In a...
Read MorePerformance Standard: The finishes of new exterior stucco walls may not perfectly match the finishes of old exterior stucco walls. Corrective Measure:...
Read MorePerformance Standard: Cracks in exterior stucco wall surfaces shall not exceed 1/8 inch in width. Corrective Measure: The remodeler will repair cracks...
Read MorePerformance Standard: No point along the bottom of any course shall be more than 1/4 inch higher or lower than any other point within 10 feet along th...
Read MorePerformance Standard: Cracks greater than 3/8 inch in width are not acceptable. Corrective Measure: The remodeler will repair cracks in excess of the ...
Read MorePerformance Standard: Joint separations exceeding 1/8 inch are unacceptable. Corrective Measure: The remodeler will caulk or repair siding as necessar...
Read MorePerformance Standard: Cracks in grouting of ceramic tile joints commonly result from normal shrinkage conditions. Corrective Measure: The remodeler wi...
Read MorePerformance Standard: The corners of adjoining resilient floor tiles shall be aligned to within 1/8 inch. Misaligned patterns are not covered unless t...
Read MorePerformance Standard: Bubbles resulting from trapped air that protrude higher than 1/16 inch from the floor are not acceptable. Corrective Measure: Th...
Read MorePerformance Standard: Readily apparent depressions or ridges exceeding 1/8 inch shall be repaired. The ridge or depression measurement is taken with t...
Read MorePerformance Standard: When stretched and secured properly, wall to wall carpeting installed as the primary floor covering shall not come up, loosen, o...
Read MorePerformance Standard: It is not unusual for carpet seams to show. However, a visible gap at the seams is not acceptable. Corrective Measure: The remod...
Read MorePerformance Standard: Brush marks shall not be readily visible on interior painted surfaces when viewed from a distance of 6 feet under normal lightin...
Read MorePerformance Standard: Cracks shall not exceed 1/8 inch in width. Corrective Measure: The remodeler will repair cracks exceeding 1/8 inch in width only...
Read MorePerformance Standard: Fading of exterior paints and stains is normal and the degree of fading depends on climatic conditions. Corrective Measure: None...
Read MorePerformance Standard: Exterior paints and stains shall not fail during the warranty period. Corrective Measure: If exterior paint or stain has peeled ...
Read MorePerformance Standard: Repairs required under these performance standards shall be finished to match the immediate surrounding areas as closely as prac...
Read MorePerformance Standard: The colors of new exterior stucco walls may not perfectly match the colors of old exterior stucco walls. Corrective Measure: Non...
Read MorePerformance Standard: Cut bricks used in the course directly below an opening shall not vary from one another in thickness by more than 1/4 inch. Corr...
Read MorePerformance Standard: Siding trim accessories shall not separate from caulking at windows or other wall openings during the warranty period. Correct...
Read MorePerformance Standard: Trim shall not separate more than 1/4 inch from the house. Corrective Measure: The remodeler will reinstall trim or caulk separa...
Read MorePerformance Standard: Resins and extractives bleeding through paint or stain, or blackening of shakes or shingles is unacceptable since bleeding can b...
Read MorePerformance Standard: Wiring shall be capable of carrying the designed load for normal residential use. Corrective Measure: The remodeler will check t...
Read MorePerformance Standard: All electrical outlets, switches, and fixtures shall operate as designed. Corrective Measure: The remodeler will repair or repla...
Read MorePerformance Standard: Ground fault interrupters are safety devices installed as part of the electrical system to provide protection against electrical...